LED Spot Light Goose Neck Type

LED Spot Light Goose Neck Type
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
Light Source TypeLED
Lighting ColorCool White
TypeIndoor
Warranty1 Year
PortableYes
RotationYes
Power(W)15 watts

LED Spotlight Goose Neck Focus Model - Dermatology Equipments
LED SPOT LIGHT is the most convenient and lightweight yet very powerful light. The stainless steel stand ensures completely rust free and tidy feel because of the easy maintenance. It can be used for various applications in various wide ranges of departments. Works on ac voltage and consumes only 10w (1/3 of a cfl tube light) Heat generated is very minimal and hence very user friendly and also reduces strain on air conditioners thus more energy is saved. The castor wheel stands is very stable and yet free to relocate. Wall mountable and table clamped model also available.

Specifications:

-> lamp type : led
-> led life : 50000 hours service life.
-> housing : polycarbonate moulding
-> colour temp : 5500k.
-> input voltage : 180~ 220 v AC.
-> working frequency : 50~60 Hz.
-> facula Lux : 60000.
-> brightness control : Adjustable
-> Models : floor stand, wall mount, table clamp.

Advantages

-> Increased Revenue.
-> Reduced Stress.
-> Redeuced Operating time.
-> Pressure less Cutting.
-> Micro-smooth Incisions.
-> Increased range of procedures.
-> No Lateral Heat
Yes! I am Interested
Get CALLBACK

Bipolar Coagulator

Bipolar Coagulator
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
Operation ModeManual
Model NumberDIGITAL 009
HandlingPortable
CategoriesSurgical Equipments
Power Supply230 volts

Description: Benefits:Solid state circuit system ensures safety procedures to delicate tissue involved for cataract ,retinal and IOL surgery.Can be used with irrigation or in the bloody field itself,to locate the bleeder easier to enable the surgeon.Useful for opththalmic surgical procedures and for delicare surgery reducing Tissue Trauma. Coagulating with saline irrigation reduces tissue heating,shrinkage,drying and sticking of coagulam to the forcep tips. Fault Diagnosis:If unit is not functioning check up the power supply and fuse.While using forceps use gloves to avoid grounding.Sticking of coagulam to the forceps tips or carbon deposit at the tip-simply clean it with knife and surgical spirit.Use separate cables or forceps for fault.Avoid direct contact of forceps tisp.

Features:
  •  Forceps,Erasers,cables are autoclavable
  •   Digital display for easy setting
  • Imported forceps and erasers can be attached
  • Power control is continuously variable between 1-9
Yes! I am Interested
Get CALLBACK

Cryo Deluxe Unit

Cryo Deluxe Unit
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
Operation ModeManual
Model Number002
HandlingPortable
CategoriesDiagnostic Equipments

Description:Cryo 002 deluxe is functionally designed to simplify cataract, retinal and glaucoma procedures by use of a variety of surgical probes. The BASCO cryo is foot operated and very sleek enabling easy handling and the pedal control enables instant freezing and defrosting. The consol face includes a pressure indicator and On-Off reading for visual indication of the system.
Yes! I am Interested
Get CALLBACK

Ophthamic Cryo

Ophthamic Cryo
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
Operation ModeManual
ConditionNew
Applicationcatarct , retinal surgery
CategoriesSurgical Equipments

CRYYO is functionally designed to simplify cataract, Retinal and glaucoma procedures by use of a variety of surgical probes. The BASCO CRYO is foot operated and very sleek enabling easy handling and the pedal control enables insatant freezing and defrosting. The console face includes a pressure indicator and ON-OFF reading for visual indication of the system.

SPECIAL FEATURES:
1. Non electric
2.Nitrous or carbon-di-oxide gases technique are used for low tempreture achievement.
3.Useful for cataract, retinal, glaucoma and intravitreous.
4.Foot control provision for easy handling and instant freezing and dfrosting
5.Low cost in use
6. Two years guarantee
7. Backed by prompt after sale service
Yes! I am Interested
Get CALLBACK

Motorized Mini Suction Pump

Motorized Mini Suction Pump
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
ModelBSM 500
Automation Grade Semi-Automatic
ApplicationHospital
BrandBASCO

MOTORISED MINI-SUCTION MACHINE ( VENTOUSE)MODEL – BSM – 500ADVANTAGES:-· Compared to Forces there is much less hazard of damaging the soft birth canal.· Least or nil injury to the skull of intracranial hemorrhage and / or facial injury or even paralysis.· Vacuum Indicator shows exact power required and can be set also can be controlled.· Our all cups will be provided with safety valves for emergency release intantly.· Suction bottle (1/2litre capacity ) autoclavable polycarbonate material supplied with the unit ( Multi purpose two in one, it can be used as a suction unit and other point can be used as a nebulizer) Widely used in OP Dept, especially for suction & delivery (Ventouse), Pediatric emergency like mucus removal. It is portable and light weight and its weight only 2 Kg. One cup will be supplied with the machine ( Long cup with safety valve) and other design cups at extra cost.· Extra safety filter, On-Off Switch, fuse will be provided for immediate replacement.GYNAEC & GENERAL APPLICATIONS:-MANUAL HAND VACCUM PUMPFor minor work with required safety negative pressure achieved. Suction pressure can be controlled or seen visually and the user can stop or proceed with the function accordingly since it is controlled by ourselves (Hand pump). Very low cost. No electricity required and hence can be moved to any place or for camp work. Silicon Vaccum Cup size available – small / medium / large.· Any make silicon cup attached.
Yes! I am Interested
View PDF
Get CALLBACK

RF Cautery

RF Cautery
  • +2
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
ApplicationClinical Purpose, Hospital
BrandBASCO

AESTHETIC AND RESTORATIVE SURGERY:- The Technique of Radio Surgery involves the passage of high frequency radio waves (2MHz) through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat, which produces steam, and results in cellular molecular dissolution of individual tissue cells. The surgeon uses a handpiece with an active electrode (different types of electrode for different applications) to transmit the radio waves. The radio waves are focused on the tissue by an antenna plate (Patient plate) that is positioned behind the tissue in contact with patient’s skin. Radio frequency is not to be confused with electro-surgery machine (surgical diathermy) or spark gap circuitry unit (electro- cautery) and uses completely new technique compared with scalpel surgery and other techniques and Radio energy does the cutting very light. The process involves the use of a very high frequency (VHF) Radio wave, 0.5 – 2 MHz, and fine needle or wire loop electrode held by the surgeon; Radio energy is passed between this curtery electrode and patient plate. It is concentrated at the needle end or wire loop electrode, resulting in the release of energy, which produces steam within the cells, thus vaporizing them and dividing the tissues. SPECIAL FEATURES:-
Radio Surgery cutting current can be more versatile than a laser for smoothing and finishing skin wounds or revising scars after skin cancer surgery. Radio frequency current technology that will help Physicians/Surgeons to fine tune the repair of surgical defects is a new application that will help surgeons make the best use of their investment in the instrument.Patient satisfaction with this technique is very high because radio surgery causes less bleeding than conventional surgery, allowing the post operative skin defects to be more easily camouflaged. Eye lid surgery:
Excellent results have ben obtained removing sedorrheic keratoses from the upper eye lid and there are many papers describing blepharplasty and simar papers.

ENT:
Radio - assissted uvulopalatoplasty, removal of vascular lession within the mouth, epistaxix hemangiomas and toungue lession removal.
Yes! I am Interested
Get CALLBACK

RF Cautery

RF Cautery
  • +1
 
Ask For Price
Product Price:  Get Latest Price

Product Details:
ApplicationHospital

AESTHETIC AND RESTORATIVE SURGERY:- The Technique of Radio Surgery involves the passage of high frequency radio waves (2MHz) through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat, which produces steam, and results in cellular molecular dissolution of individual tissue cells. The surgeon uses a handpiece with an active electrode (different types of electrode for different applications) to transmit the radio waves. The radio waves are focused on the tissue by an antenna plate (Patient plate) that is positioned behind the tissue in contact with patient’s skin. Radio frequency is not to be confused with electro-surgery machine (surgical diathermy) or spark gap circuitry unit (electro- cautery) and uses completely new technique compared with scalpel surgery and other techniques and Radio energy does the cutting very light. The process involves the use of a very high frequency (VHF) Radio wave, 0.5 – 2 MHz, and fine needle or wire loop electrode held by the surgeon; Radio energy is passed between this curtery electrode and patient plate. It is concentrated at the needle end or wire loop electrode, resulting in the release of energy, which produces steam within the cells, thus vaporizing them and dividing the tissues. SPECIAL FEATURES:-
Radio Surgery cutting current can be more versatile than a laser for smoothing and finishing skin wounds or revising scars after skin cancer surgery. Radio frequency current technology that will help Physicians/Surgeons to fine tune the repair of surgical defects is a new application that will help surgeons make the best use of their investment in the instrument.Patient satisfaction with this technique is very high because radio surgery causes less bleeding than conventional surgery, allowing the post operative skin defects to be more easily camouflaged. PLASTIC SURGERY:-Face Lift, Breast Reconstruction, excision of skin lesions, Blepharoplasty. TREATING FACIAL TELANGIECTASIAS:- Removal of telangiectasias by conventional methods like Electro – cautery etc.: Patients experience discomfort and intolerable pain – efforts and surgery must be discontinued. In addition, some patients will develop small dells or depressions associated with dessication, crust formation and healing.
DERMATOLOGY – WARTS:- Warts are common cutaneous and many different means have been used in treatment of them. A Loop electrode ¼ “diameter (6.35mm) is inserted around the wart and pushed down the center rather than straight across. Care must be taken not to penetrate into the dermis because this may lead to scar formation. Little scarring, if any, will result in the affected epidermis alone being removed and the dermis left intact. For very smaller warts and flat warts, loop (1-2mm in diameter) electrode is not advisable, and pointed electrode is commonly used. Loop electrode is suitable for periungual and subungual warts, condyloma, accuminata and plantar warts.The high frequency radio surgical instrument as proven to be a boom for dermatological and plastic surgery, as it allows many more procedures to be accomplished in an office setting. In addition, patient acceptance has been high, because of more rapid healing time and superior cosmetic results as with cold knife. For example, Facial telangiectasias by radio frequency minimized discomfort and completely eliminated dells or depression and sever pain or bleeding. With it, one can treat the patient’s face and neck area in one sitting and it can also be operated in very low current setting compared to other methods with higher frequency.