Body Material | Plastic |
Light Color | White |
Brightness | 30000 lux |
Usage/Application | Hospital |
Brand | Basco |
Light Source Type | LED |
Positioning | Headlight |
Model Name/Number | ENT HL |
Focus Dia | no focus |
Country of Origin | Made in India |
Light Spot Diameter | 3 Inches approx |
Maximum Illumination | 3 Watts |
Operating Time | 1.5 Hours |
Color Temperature | 6000K |
Charging Time | 2.5 hrs |
Usage/Application | Operation Theater |
Model Name/Number | ZD 2015 |
Positioning | Mobile |
Brand | BASCO |
Light Source Type | LED |
Brightness | 60000 Lux |
Number Of Domes | One |
Color Specification | Single Colour |
Lighting Color | WHITE |
Power | 20 WATTS |
Field Diameter | COULD BE ADJUSTED |
Country of Origin | Made in India |
Model Name/Number | Z 2018 |
Brand | BASCO |
Power | 10WATTS |
Lighting Color | Warm White |
Lighting Type | LED |
Input Voltage | 180-230V |
Warranty | 1 YEAR |
Base Type | MOVABLE |
Housing | STAND |
Country of Origin | Made in India |
Model Name/Number | RF B 2 |
Usage/Application | Hospital |
Frequency | 2mHZ |
Brand | BASCO |
Country of Origin | Made in India |
The Technique of Radio Surgery involves the passage of high frequency radio waves (2MHz) through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat, which produces steam, and results in cellular molecular dissolution of individual tissue cells. The surgeon uses a handpiece with an active electrode (different types of electrode for different applications) to transmit the radio waves. The radio waves are focused on the tissue by an antenna plate (Patient plate) that is positioned behind the tissue in contact with patient’s skin. Radio frequency is not to be confused with electro-surgery machine (surgical diathermy) or spark gap circuitry unit (electro- cautery) and uses completely new technique compared with scalpel surgery and other techniques and Radio energy does the cutting very light. The process involves the use of a very high frequency (VHF) Radio wave, 0.5 – 2 MHz, and fine needle or wire loop electrode held by the surgeon; Radio energy is passed between this curtery electrode and patient plate. It is concentrated at the needle end or wire loop electrode, resulting in the release of energy, which produces steam within the cells, thus vaporizing them and dividing the tissues.
Features:
Radio Surgery cutting current can be more versatile than a laser for smoothing and finishing skin wounds or revising scars after skin cancer surgery. Radio frequency current technology that will help Physicians/Surgeons to fine tune the repair of surgical defects is a new application that will help surgeons make the best use of their investment in the instrument.Patient satisfaction with this technique is very high because radio surgery causes less bleeding than conventional surgery, allowing the post operative skin defects to be more easily camouflaged.
Plastic Surgery
Face Lift, Breast Reconstruction, excision of skin lesions, Blepharoplasty.
Treating Facial telangiectasias:
Removal of telangiectasias by conventional methods like Electro – cautery etc.: Patients experience discomfort and intolerable pain – efforts and surgery must be discontinued. In addition, some patients will develop small dells or depressions associated with dessication, crust formation and healing.
Dermatology Warts:
Warts are common cutaneous and many different means have been used in treatment of them. A Loop electrode ¼ “diameter (6.35mm) is inserted around the wart and pushed down the center rather than straight across. Care must be taken not to penetrate into the dermis because this may lead to scar formation. Little scarring, if any, will result in the affected epidermis alone being removed and the dermis left intact. For very smaller warts and flat warts, loop (1-2mm in diameter) electrode is not advisable, and pointed electrode is commonly used. Loop electrode is suitable for periungual and subungual warts, condyloma, accuminata and plantar warts.The high frequency radio surgical instrument as proven to be a boom for dermatological and plastic surgery, as it allows many more procedures to be accomplished in an office setting. In addition, patient acceptance has been high, because of more rapid healing time and superior cosmetic results as with cold knife. For example, Facial telangiectasias by radio frequency minimized discomfort and completely eliminated dells or depression and sever pain or bleeding. With it, one can treat the patient’s face and neck area in one sitting and it can also be operated in very low current setting compared to other methods with higher frequency.
Working Distance | 200-600 mm |
Brand | Basco |
Magnification | 2x, 2.5x, 3x, 3.5x and 4x |
Our operating loupes have well thought out design that allows user to make quick Effortless , spontaneous adjustment of the loupe. Ample area of field vision High optical quality allows excellent stereoscopic image without discolouration and Diplopia , Thus needs least or nil squinting of eyes. Available with different types of metal and plastic frames to suit the convenience & choice of Users. Comes with variety of aesthetic colour mountings with retaining strap and with enclosure Case for loupes.
Models:
Model Magnification Working Distance
BL 2.5x 250mm
BL 3.3x 350mm
BL 3x 200-600mm zoom
BL 4.4x 400mm
High- precison Diagnostic/ inspection Loupes for various specially uses
Made out of high-precision optics, keeping in mind the varied types of end-users and different inspection styles. BASCO Loupes are priced reasonably & really inexpensive compared to importes equivalents, yet there is no compromise on quality. In construction of the Loupes end-user's convenience, product light weight and durability have been taken into account as essential factors.
Versatile in Application
These Binocular-Loupes are excellent visual inspection aids for General Surgery, Opthalmology, Vascular/ Plastic/ neuro Surgery, Veterinary Medicine, Paediatrics, Gynaecology and Orthopaedics.
Equally and critically useful for Engineering, Quality control Checks, Electronic Assembly, and similar areas where extremely high accuracy / precision work and /or checking or fault diagnosis is essential.
Essential Features:-
Model:BL-2.5X
Plain light-weight metal frame with spring type ear-grip for push-front / pull-back spontaneous adjustment. No need for retaining strap or rope. Excellent for users not wearing power glasses.
Plain metal frame for viewing with bare eyes (for those not using power glasses)
Model:BL-3X
Plastic light-weight frame with screw type adjustment facility for Precise IPD selection.
Light-weight Metal frame. Provided with Adjustment ring to enable adjustment of magnification, visual field dia., working distance. Focussing can be varied with the working distance from 200 to 600 mm (Zoom).
Model: BL-4X
Plastic frame with rotary strap facility for better or better grip / retaining. Ideal for power glass users.
Elegant Light-weight Metal frame with good ear grip for those using Power glasses.
Usage/Application | Operation Theater |
Model Name/Number | HL 2000 |
Positioning | Mobile |
Brand | BASCO |
Light Source Type | Halogen |
Number Of Domes | One |
Color Specification | Single Colour |
Color | WARM WHITE |
Country of Origin | Made in India |
Brand | Basco |
Material | Stainless Steel |
Usage | ENT |
Packaging Type | Box |
Rust Proof | Yes |
Size | 14mm - 30mm |
Features:
Magnification | 5X, 10X, 20X |
Brand | Basco |
Interpupillary Distance | 50 to 75mm |
Weight | Approx 60 Kg |
Auxiliary Lense | 200 mm |
Power Supply | 220 to 240 Volts, 50 Hz |
Power Consumption | 15v-150w or 24v-250w |
Intensity | 60,000 to 80,000 LUX |
Arm Rotation | 360 Degree |
Head Inclination | 10 to-100 Degree |
Field of Illumination | 40mm to 70mm for (200mm objective) |
We are engaged in offering high quality range of Stereoscopic Microscope to our esteemed customers.
Features:
Light Source Type | LED |
Positioning | Headlight,Mobile |
Brightness | 3 watts and 5 watts |
Light Colour | White |
Usage/Application | Surgical, Dental, Medical |
Power Supply | 150-300 V AC |
Magnification | 2.5X |
Light Head Power | 6 V/ 20 Watt |
Special Features: