Usage/Application | Hospital |
Warranty | 1 Year |
Weight | 3 kg approx |
Body Material | MS and PVC |
Usage | Hospital |
Brand | Basco |
Operation Mode | Manual |
Voltage | 220 V |
Features:
Procedures:
Description:
Model | PTC 2 |
Application | Hospital |
Brand | Basco |
Weight | 110 gm |
Working Temperature | 700 degree C |
Tip Length | 30 mm (115 mm on request) |
Voltage | 2.4 V to 3 V |
Operating Tip | Straight or Curved |
Specifications:
Brand | Basco |
Usage/Application | Hospital |
Warranty | 1 Year |
Body Material | MS |
Frequency | 50 Hz |
Voltage | 220 V |
Material | Polycarbonate |
Wattage | 20 W |
Shape | Round |
Lighting Source | LED |
Usage/Application | For surgery |
Input Voltage | 180 - 220 V |
Lamp Life | 7000 hours |
Brightness | 6000 Lux |
Brand | Basco |
Lamp Type | UVA / UVB |
Light Source Type | CFL |
Positioning | Mobile |
Brand | Basco |
Adjustable Screen | Yes |
Lighting Colour | UAV / UVB |
Model Name/Number | SP -603 |
Voltage | 230 V |
Frequency | 50 Hz |
Power | 4 Watt |
Specifications:
Lighting Type | LED |
Brand | Basco |
Automation Grade | Manual |
Voltage | 220 V |
Power (W) | 100 Watt |
Application | Clinical Purpose, Hospital |
Power Supply | 230 V AC |
No. of Pin | 3 Pin |
The patient should be assured of the usefulness and non-invasive nature of the examination.Since ointments,exudates,cosmetics and soap may flouresce. The skin should be well cleansed before examination. The lamp should be on for atleast a inute to attain optimum intensity.This duration also helps the investigator for darkness adaptation. The light source should be four to five inches from the lesion.
Connect the Mains plug in the 3-pin socket.Swicth on the Mains button to the ON position. Then push the choke button once for instant glow. The on-off swicth is selected by switching to the upward position for Ultra Violet and downward for the White Tube.
Frequency | 2mHZ |
Application | Veterinary Purpose |
Bipolar Coag | Yes |
Coagulation | 100 Watts on 1000 ohm |
Weight Kg | 4 Kg |
Brand | Basco |
Power | 150 Watt |
Voltage | 220 V |
Body Material | MS |
The Technique of Radio Surgery involves the passage of high frequency radio waves (2MHz) through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat, which produces steam, and results in cellular molecular dissolution of individual tissue cells. The surgeon uses a handpiece with an active electrode (different types of electrode for different applications) to transmit the radio waves. The radio waves are focused on the tissue by an antenna plate (Patient plate) that is positioned behind the tissue in contact with patient’s skin. Radio frequency is not to be confused with electro-surgery machine (surgical diathermy) or spark gap circuitry unit (electro- cautery) and uses completely new technique compared with scalpel surgery and other techniques and Radio energy does the cutting very light. The process involves the use of a very high frequency (VHF) Radio wave, 0.5 – 2 MHz, and fine needle or wire loop electrode held by the surgeon; Radio energy is passed between this curtery electrode and patient plate. It is concentrated at the needle end or wire loop electrode, resulting in the release of energy, which produces steam within the cells, thus vaporizing them and dividing the tissues.
Special Features:-
Radio Surgery cutting current can be more versatile than a laser for smoothing and finishing skin wounds or revising scars after skin cancer surgery. Radio frequency current technology that will help Physicians/Surgeons to fine tune the repair of surgical defects is a new application that will help surgeons make the best use of their investment in the instrument.Patient satisfaction with this technique is very high because radio surgery causes less bleeding than conventional surgery, allowing the post operative skin defects to be more easily camouflaged.
Plastic Surgery:-
Face Lift, Breast Reconstruction, excision of skin lesions, Blepharoplasty.
Treating Facial Telangiectasias:-
Removal of telangiectasias by conventional methods like Electro – cautery etc.: Patients experience discomfort and intolerable pain – efforts and surgery must be discontinued. In addition, some patients will develop small dells or depressions associated with dessication, crust formation and healing.
Dermatology Warts:-
Warts are common cutaneous and many different means have been used in treatment of them. A Loop electrode ¼ “diameter (6.35mm) is inserted around the wart and pushed down the center rather than straight across. Care must be taken not to penetrate into the dermis because this may lead to scar formation. Little scarring, if any, will result in the affected epidermis alone being removed and the dermis left intact. For very smaller warts and flat warts, loop (1-2mm in diameter) electrode is not advisable, and pointed electrode is commonly used. Loop electrode is suitable for periungual and subungual warts, condyloma, accuminata and plantar warts.The high frequency radio surgical instrument as proven to be a boom for dermatological and plastic surgery, as it allows many more procedures to be accomplished in an office setting. In addition, patient acceptance has been high, because of more rapid healing time and superior cosmetic results as with cold knife. For example, Facial telangiectasias by radio frequency minimized discomfort and completely eliminated dells or depression and sever pain or bleeding. With it, one can treat the patient’s face and neck area in one sitting and it can also be operated in very low current setting compared to other methods with higher frequency.
Usage/Application | Hospital |
Material | Stainless Steel |
Categories | Holding Instruments |
Brand | Basco |
Automation Grade | Manual |
Capacity | 150-200 ml |
Dermajet B1, is now the leading high pressure, needle - less, automatic injector because of its simplicity, realiablilty, versatality and affordability and its ideal usefulemess in the case of atients who fear / hate needles
Ideal for providing local anaesthesia, vaccination, steriods in treating
Caution:
Salient Features:
Usage/Application | Hospital |
Frequency | 2 mHZ |
Coagulation | 100 Watts on 1000 ohm |
Warranty | 1 Year |
Weight Kg | 4 Kg |
Brand | Basco |
Power | 150 Watt |
Voltage | 220 V |
Body Material | MS |
high frequency radio surgery unit consisting of monoterminal cutting, coagulation and fulguration to trat wide variety of skin disorders with excellent results. Radio surgery is a type of electrosurgery used to destruct the tissue for desire3d effect like cutting , coagulation by passing ultra high frequency radio waves. In addition to fulguration and desiccation which makes the equipment highly versatile.
TYPES OF TISSUE DESTRUCTION
Three types of surgery can be performed by this equipment
1. Electrosection ( cutting and coagulation)
2. Electrocoagulation
3. Fulguration
ELECTROSECTION
It consists of fully rectified wave form ( 50% cutting and 50% coagulation) it Provides instant hemostasis along with cutting. it provides bloodless surgical field and is most often used wave form for electrosectioning.
ELECTROCOAGULATION
It consists of partially rectified waveform (90% COAGULATION AND 0% cutting) provides instant hemostat with more tissue destruction ( Touch the bleeder holding artery forceps by loup electrode for coagulation).
FULGURATION
Superficial tissue destruction
LESSIONS TREATED
· Acrochordons
· Moles & greckles
· For skin incisions
· Excisions of cysts
· Seborrhoeic keratosis
· Xanthelasma palpebram
· Granuloma pyogenicum
· Acne keliodales nuchae
· Dematofibroma
· Mucocele
· Verruca
· Anginomas
· Molluscum conatgiosum
· Epidermal verrucous naevi ( combination with dermabrasion)
· Pitted scares ( combination with subcision and dermabrasion)
· Rhinophyma
· Small malignant leision etc
· Epilation
Usage/Application | Operation Theater |
Brand | Basco |
Light Source Type | LED |
Number Of Domes | 1 |
Positioning | Floor Stand, Wall Mount, Table Clam |
Rotation | Yes |
LED Life | 50000 hours |
Housing Material | Poly-Carbonate |
Color Temperature | 5500 K |
Input Voltage | 180-220 V |
Frequency | 50-60 Hz |
Facula Lux | 60000 LUX |
Material | Plastic |
Disposable | Yes |
Available Sizes | 0.5mm. 2.0mm. 2.5mm. 3.0mm. 3.5mm. 4.0mm |
Brand | Basco |
Length | 5-10 Inch |
Syringe Filled Capacity | 3 ml |
Brand | Basco |
Application | Operation Theater |
Magnification | 6X |
Working Distance | 250mm |
Viewing Distance | 500mm |
Viewing Area | 145mm |
Voltage | 220V - 240V AC(+/- 10V) |
Model Name/Number | B 202 |
Frequency | 50 Hz |
Usage | Hospital |
Weight Kg | 1 Kg |
Brand | Basco |
Usage/Application | Hospital |
Brand | Basco |
Application | Hospital |
Size | 110mm x 33 mm |
Magnification | 10x to 200x |
Power Supply | 5 V DC |
Special Features:
Description:
Usage/Application | Hospital |
Brand | Basco |
Material | Stainless Steel |
Power Supply | 5 V DC |
PC Interface | Mini MB 2.0 |
Brand | Basco |
Model Name/Number | LNC196 |
Material | Stainless Steel |
Application | Hospital |
Automation Grade | Manual |
Warranty | 1 Year |
Capacity | 300 ml |
To meet the various requirements of the customers, we are involved in offering a wide assortment of Liquid Nitrogen Cryogenic System.
Special Features:
Supplied With Kit:
Usage/Application | Operation Theater |
Positioning | Mobile |
Model Name/Number | HL 2000 |
Brand | BASCO |
Light Source Type | Halogen |
Number Of Domes | One |
Color Specification | Single Colour |
Lighting Color | WARM WHITE |
Country of Origin | Made in India |
Model Name/Number | Z 2018 |
Brand | BASCO |
Power | 10 WATTS |
Lighting Color | Warm White |
Lighting Type | LED |
Input Voltage | 180-230V |
Warranty | 1 YEAR |
Base Type | MOVABLE |
Housing | STAND |
Country of Origin | Made in India |
Usage/Application | Hospital, Clinic, etc |
Voltage | 220 V |
Brand | Basco |
Power | 23 Watt |
Frequency | 50 Hz |
Portable | Yes |
Automation Grade | Semi-Automatic |
Power Source | Electric |
Gross Weight | 2.2 Kg |
Salient Features:-
Advantages & Treatment:-
No Of Treatments & Duration:-
Age and skin condition will determine the number of treatments required to achieve optimum effect. For most skin problems, a minimum of six treatments recommended.
Dermabrasion works in two ways:-
Correction:-
Abrasive action gently removing the surface layer of the dead skin allowing a smoother, fresher skin to emerge.
Stimulation:-
Vacuum action of the system stimulates micro circulation, thus increasing blood supply for skin regeneration. Also induces formation of new collagen & estin to improve skin texture and elasticity.
Overall Benefits:-
Usage/Application | Hospital and Clinic |
Brand | ROHS 540 |
Material | Medical Grade Plastic |
Available Size | 0.5mm,0.75mm,1mm,1.5mm,2mm,2.5mm,3mm |
Number of Needles | 540 Slender |
Dermarollers are used for the treatment process called microneedling or skin needling. It is a form of callogen induction therapy, quickly gaining popularity in the western countries. Dermarollers are already highly popular in parts of Asia where skin needling has been practising for sometime.
It will increase 4% to 87% absorption of skin and hair products by the blocked pores which stimulates hormones effectively and naturally without inducing hyper pigmentation and sun sensitivity.It improve the blood supply on scalps,face,neck,skin and throughout the body.
Brand | Brasco |
Material | Stainless Steel |
Application | Hospital |
Size | F,M and C |
Length | 5-6 inch |
Dermabrasion procedures are surgical, invasive procedures that typically require a local anaesthetic. Often they are performed in surgical suites or in professional medical centers.. Afterward, the skin is normally very red and raw-looking. Depending on the level of skin removal with dermabrasion, it takes an average of 7–30 days for the skin to fully heal (re-epithelialize). Often this procedure was performed for deeper acne scarring and deep surgical scars. The purpose of surgical dermabrasion is to help diminish the appearance of deeper scars and skin imperfections. Often the goal is to smooth the skin and, in the process, remove small scars (as from acne), uneven skin tone from scars or birthmarks, sun damage, tattoos, age spots, stretch marks or fine wrinkles. Dermabrsion afford an overall lower cost (affordable) and may provide similar superior results as newer laser method for certain skin conditions
Working Distance | 200 to 600 mm |
Brand | Basco |
Color | Black |
Magnification | 2.5x, 3x |